Monarch Nice3000 Parallel Operation Process
Xi'an Husheng Mechanical-Electronic Co., Ltd After more than a decade of research on the Monarch system, the following is the process for sharing the parallel operation of the Monarch 3000.Hope to help you solve some technical problems.
1.Two elevator main board on the J5 short OFF
2.CAN+ of main elevator plug-in CN3 is connected to Y5 point of main elevator CN7
3. CAN- of the main elevator plug-in CN3 is connected to CAN- of the Sub-elevator CN3
4. Main elevator plug-in CN7's M5 point is connected to Sub-elevatorCN7's Y5 point
5. CAN+ of sub-elevator CN3 is connected to M5 of sub-elevator CN7
6. The COM of main elevator CN3 is connected to the COM of sub-elevator CN3
7. Main elevator car roof board 1, 2, 3 to OFF, 45 to ON
8. Sub-elevator car roof board 2 3 to OFF, 1 4 5 to ON
2,Parameter setting
(1) Main and sub-elevator F6-07 set to 2
(2) Main elevator F6-8 set to 1 ,subelevator F6-8 set to 2
(3) Main and sub-elevator F6-9 set to 4 (open compatible parallel mode)
(4) F5-30 Y5 function selection Set to 14
Xi'an Husheng Mechanical-Electronic Co., Ltd is committed to meeting the diversified needs of domestic and foreign clients for elevators and escalators.We specialize in manufacturing various elevator parts and escalator parts to supply our clients all over the world, and our brands mainly include OTIS ,KONE,MONARCH,THYSEEN,LG-SIGMA,SCHINDLER,MITSUBISHI,HITACHI.If you have other technical questions or parts needs, please feel free to contact us.